Manage Serverless Agent Logs
Workload logs remain with whatever log setup you have on your task container.
Instrumentation logs, namely the logs associated with the Workload Agent, are stored in a separate log group created by the serverless instrumentation stack:
<stack_name>-SysdigLogGroup-<uid>
Currently, the log group name for instrumentation cannot be edited.
You can configure the instrumentation logs by using the environment variables described below.
Set Global Log Level
The environment variable SYSDIG_LOGGING
sets the global instrumentation log level.
It defaults to info
.
Available options are: silent
| fatal
| critical
| error
| warning
| info
| debug
| trace
.
Configure the Logging Mechanism
As of serverless agent version 4.0.0, you can fine-tune the Workload Agent as described in Manage Agent Log Levels as follows:
- Prevent excessive logging from certain components
- Enable extra logging from specific components for troubleshooting
Use the environment variable SYSDIG_EXTRA_CONF
to do so.
The following example shows the configuration string sets the global log level to info
and the log level of the security_mgr
component to warning
.
SYSDIG_EXTRA_CONF="log: { console_priority: info, console_priority_by_component: [ 'security_mgr: warning' ] }"
Log Forwarding
By default, the instrumentation logs are wrapped as JSON ojects and forwarded to the <stack_name>-SysdigLogGroup-<uid>
log group.
Configure log forwarding using the following environment variables:
Environment Variable | Default | Description |
---|---|---|
SYSDIG_ENABLE_LOG_FORWARD | true | Enables and disables the log forwarding. Set to false to disable the log forwarding. |
SYSDIG_LOG_FORWARD_FORMAT | json | Defines the format of the instrumentation log events. Set to text to get logs in plaintext. |
Disable Log Forwarding
Use the following configuration to disable the log forwarding. If you do so, the Workload Agent logs will be stored along with the workload logs.
SYSDIG_ENABLE_LOG_FORWARD="false"
Note that when log forwarding is disabled, the log forwarding format switches to text
automatically.
Forward Logs in Text Format
To forward instrumentation logs to text format, use the following configuration string:
SYSDIG_LOG_FORWARD_FORMAT="text"
You can also configure the log Workload Agent to forward logs to a different TCP endpoint by using the following environment variables:
Environment Variable | Default | Description |
---|---|---|
SYSDIG_LOG_LISTEN_PORT | 32000 | The port of the log listener. |
SYSDIG_LOG_FORWARD_ADDR | localhost:32000 | The TCP endpoint the logwriter of the Workload Agent listens. |
SYSDIG_BUFFER_SIZE | 1024 | The size in bytes of the rx buffer of the TCP listener. Default 1024 . |
SYSDIG_DEADLINE_SECONDS | 3 | Connection deadline. You can increase it, if clients take longer to connect. |